Start Inside. Clean and Inspect
Inspect Air Filter and Date
Inspect Air Filter and Date
Initial the filter
Replaced Filter
Yes
No
Filter Size
14 X 30 X 1
14 X 25 X 1
14 X 20 X 1
16 X 20 X 1
16 X 24 X 1
16 X 25 X 1
20 X 25 X 1
20 X 24 X 1
20 X 20 X 1
Aprilair 610
Aprilair 810
Aprilair 413
Aprilair 213
Aprilair 501
Other
Clean Condensate Drain System
Check Leak Detector - "Safe - T - Switch"
Check Leak Detector - "Safe - T - Switch"
Clean and Test Condensate Drain System
Clean and Test Condensate Drain System
With 1 gallon water + 8oz CLR
Make sure water is coming out of drain termination.
Make sure water is coming out of drain termination.
Clean P-Trap
Clean P-Trap
Flush Condensate Pump
Flush Condensate Pump
Check The Blower
Test Blower Capacitor
Test Blower Capacitor
Inspect Blower Wheel Cleanliness
Inspect Blower Wheel Cleanliness
Shut Down Humidifier
Close Bypass Damper
Close Bypass Damper
Shut Off Humidistat
Shut Off Humidistat
Leave Water Valve On
Leave Water Valve On
TXV or Fixed Metering Device
TXV
TXV
Fixed Metering Device
Fixed Metering Device
Non-Invasive Maintenance - Inside
Run system for 15 minutes to establish equalized system
Run system for 15 minutes to establish equalized system
Suction Line Side
Take Suction Line Temperature at Coil Outlet
Return Temperature at Blower Inlet
Subtract 35 (Coil Design Temp)
Add Super Heat (12-15 degrees)
Subtotal
Subtotal should = suction line temp +- 5 degrees
Test Static Pressure
Test At Least One Register For Air Flow
Test At Least One Register For Air Flow
Total System Static Pressure - w.c
Test Temperature Split
Static Drop Across Wet Evaporator Coil
Test Temperature Split at Coil - DELTA-T
Check supply temperature 4-6 feet away from evaporator coil. Split should be 15-22 degrees.
Outside
Liquide Line Side
Outside Temperature - At the Coil
Inlet Temperature
Add Ambient temperature + COTA
Subtract Subcooling
Subtotal
Subtotal should = liquid line temp +- 3 degrees
Clean Electrical Compartment
Power Off Disconnect
Power Off Disconnect
Clean and Test Compressor Contactor
Clean and Test Compressor Contactor
Use Contact Cleaner
Check and Tighten Electrical Connections
Check and Tighten Electrical Connections
Check Compressor Blanket
Check Compressor Blanket
Test Condenser Run Capacitors
Test Condenser Run Capacitors
Check Contactor Ohm's
Check Contactor Ohm's
Clean Condenser
Shut down system at thermostat.
Shut down system at thermostat.
DO NOT REMOVE DISCONNECT
Clean Condenser Coil
Clean Condenser Coil
Coil cleaner ratio 4oz to 1 gallon water
Wrap Up
Check and Update Thermostat Software
Check and Update Thermostat Software
Reset All Maintenance Reminders
Reset All Maintenance Reminders
Review Any Thermostat Instructions with Homowner
Review Any Thermostat Instructions with Homowner
Set for Customer Desired Temperature and Operation
Set for Customer Desired Temperature and Operation
A/C System Vitals
Grade Of System
Good
Fair
Poor
Closing Out Notes